Metrologic Instruments Laser Scanner Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czytniki kodów kreskowych Metrologic Instruments Laser Scanner. Metrologic Instruments Laser Scanner User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 2

6³999994Load KeyboardWedge DefaultsFigure 2: Keyboard WedgeInterfaceINSTALLATION FOR KEYBOARD WEDGE INTERFACE1. Follow the “Getting Started” steps on

Strona 3 - LOCATIONS

7Figure 3: Stand-AloneKeyboard InterfaceINSTALLATION FOR STAND-ALONE KEYBOARD INTERFACE1. Follow the “Getting Started” steps onpage 3.2. Turn off th

Strona 4 - TABLE OF CONTENTS

8Figure 4a: POS Dip SwitchFigure 4b: USB, InterfaceINSTALLATION FOR USB INTERFACE1. Follow the “Getting Started” steps on page 3.2. Turn off the host

Strona 5 - INTRODUCTION

9INSTALLATION FOR RS232 OR LIGHT PEN INTERFACES1. Follow the “Getting Started” steps onpage 3.2. Turn off the host system.3. Connect the PowerLink

Strona 6 - SCANNER and Accessories

10INSTALLATION FOR RS232 OR LIGHT PEN INTERFACESStep 10, page 9 continued.For RS232 Communication:Scan 1st ³999998Recall DefaultsScan 2nd ³415554Ena

Strona 7 - GETTING STARTED

11INSTALLATION OF AN AUXILIARY SCANNER1. Turn off the host system.2. Connect the round end of the PowerLink RS232 AUX cable[ MLPN 54-54667A ] to the

Strona 8

12INSTALLATION OF AN AUXILIARY SCANNER11. Configure the auxiliary scanner to send formatteddata to the MS7220. Normal slave mode operationwill only re

Strona 9 - Figure 1: OCIA, Interface

13SCANNER PARTSn Output Windowo Red LEDp Green LEDq Speakerr Side Covers Cable Doort Cable Jack Coveru Horizontal Mount Basev Multi-Function Button(

Strona 10 - Interface

14POWER SAVE MODES AND THE MULTI-FUNCTION BUTTONThe MS7220 has five programmable power save modes. Refer to theMetroSelect Programming Guide for addi

Strona 11 - Keyboard Interface

15POWER SAVE MODES AND THE MULTI-FUNCTION BUTTONCHANGING THE BEEPER TONEA Short (<3 second) depression and the beepertone will change. The new ton

Strona 13 - Light Pen Interface

16AUDIBLE INDICATORSWhen the MS7220 scanner is in operation, it provides audible feedback. Thesesounds indicate the status of the scanner. Eight set

Strona 14 - Step 10, page 9 continued

17FAILURE MODESFlashing Green and One Razzberry ToneThis indicates the scanner has experienced a laser subsystemfailure. Return the unit for repair a

Strona 15 - Continued on page 12

18VISUAL INDICATORSThere is a red LED and a green LED on the front of the MS7220. When thescanner is on, the flashing or constant illumination of the

Strona 16 - Reserve Code 32

19LABELSEach scanner has a label on the back of the unit. The label contains informationsuch as the model number, date of manufacture, and the serial

Strona 17 - CANNER PARTS

20SCAN VOLUME (DEFAULT)(BASED ON 100% UPC BAR CODES)Figure 10: Top View Scan Volume (Default)Figure 11: Side View Scan Volume (Default)Specifications

Strona 18

21DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH(BASED ON 100% UPC BAR CODES)Figure 12: Top View of Default Depth of FieldSpecifications subject to

Strona 19 - OWER SAVE MODE

22DEPTH OF FIELD BY MINIMUM BAR CODE ELEMENT WIDTH(BASED ON 100% UPC BAR CODES)Figure 13: Side View of Default Depth of FieldSpecifications subject to

Strona 20 - MLPN 00-02407)

23EAS DEACTIVATION ANTENNASW1 and SW2 are the switch banks inside the CheckPoint Device that set thedeactivation range. Metrologic recommends end use

Strona 21 - FAILURE MODES

24TROUBLESHOOTING GUIDEThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-METRO or 1-800-436-3876 to p

Strona 22 - VISUAL INDICATORS

25TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe unit is scanninga particularsymbology that is notenabled.UPC/EAN, Code 39,in

Strona 23

iiLOCATIONS CORPORATE HEADQUARTERS North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO90 Coles Road Tel: 856-228-8100Blackwoo

Strona 24 - SCAN VOLUME (DEFAULT)

26TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe bar code mayhave been printedincorrectly.Check if it is a checkdigit/charact

Strona 25 - (BASED ON 100% UPC BAR CODES)

27TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONAlphacharactersshow as lowercase.The computer is inCaps Lock mode.Enable Caps Lo

Strona 26

28TROUBLESHOOTING GUIDE (CONTINUED)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONCharacters arebeing dropped.Intercharacter delayneeds to be added tothe transmit

Strona 27 - MAINTENANCE

29RS232 DEMONSTRATION PROGRAMIf an RS232 scanner is not communicating with your IBM compatible PC,key in the following BASIC program to test that the

Strona 28 - TROUBLESHOOTING GUIDE

30APPLICATIONS AND PROTOCOLSThe model number on each scanner includes the scanner number and factorydefault communications protocol.ScannerVersionIden

Strona 29

31DESIGN SPECIFICATIONSMS7220 DESIGN SPECIFICATIONSOPERATIONALLight Source: VLD 650 ± 10 nmLaser Power: 0.678 mW maximumDepth of Field: 0 mm to 215 mm

Strona 30

32DESIGN SPECIFICATIONSMS7220 DESIGN SPECIFICATIONSELECTRICALInput Voltage: 5.2VDC ± 0.25VPower: 1.9 WOperating Current: 360 mADC Transformers: Class

Strona 31

33DEFAULT SETTINGSMany functions of the scanner can be "programmed" - that is, enabled ordisabled. The scanner is shipped from the factory

Strona 32 - MLPN 54-54667]

34DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBW USBSpaces High as Code 39aBars High as ScannedaSpaces High as ScannedaDT

Strona 33 - RS232 DEMONSTRATION PROGRAM

35DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBW USBSame Symbol RescanTimeout: 2000 msecsaaaaa aIntercharacter DelayProgr

Strona 34 - MLPN 00-02407) or MetroSet

iiiTABLE OF CONTENTSIntroduction ... 1Scanner a

Strona 35 - DESIGN SPECIFICATIONS

36DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBW USB8 Data Bitsa7 Data Bits*aTransmit Sanyo IDCharactersaaaNixdorf IDaaaL

Strona 36

37DEFAULT SETTINGS (CONTINUED)Parameter Default OCIA RS-232LightPenIBM46XXKBW USBBookland 977 (2 digit)Supplemental RequirementaaaaaaSupplements are n

Strona 37 - DEFAULT SETTINGS

38DEFAULT SETTINGS (CONTINUED)Default settings for “Aux” interfaceThe secondary scanner and the MS7320 always communicate via RS232. Datais relayed t

Strona 38 - DEFAULT SETTINGS (CONTINUED)

39MS7220 STANDS Vertical Stand Kit [ MLPN 46-46405 ]See page 40 for installation instructions.Kit Includes:a. #8 x 1 round head wood screw [ MLPN 18-

Strona 39

40MS7220 STANDSVertical Stand Installation [ MLPN 46-46405 ]Remove the three screwssecuring the cable cover to theunit and slide it up and off thescan

Strona 40

41MS7220 STANDSOptional Flexible Stand Installation [ MLPN 46-46404 ]Remove the three screwssecuring the cable cover to theunit and slide it up and of

Strona 41 - Depth of Field

42SCANNER AND CABLE TERMINATIONSScanner Pinout ConnectionsThe MS7220 scanner interfaces terminate to 10-pin modular jacks located onthe back of the un

Strona 42 - EFAULT SETTINGS (CONTINUED)

43SCANNER AND CABLE TERMINATIONS (CONTINUED)Figure 16: Scanner Interface PortsMS7220-37Keyboard Wedge, StandAlone Keyboard or USBMS7220-37RS-232 or L

Strona 43 - MLPN 46-46404 ]

44SCANNER AND CABLE TERMINATIONS (CONTINUED)Cable Connector Configurations (Host End)PowerLink Cable MLPN 54-54xxx*Pin Function1 Shield Ground2 RS-232

Strona 44 - MS7220 STANDS

45SCANNER AND CABLE TERMINATIONS (CONTINUED)Cable Connector ConfigurationThe PowerLink cable is terminated with a 5-pin DIN female connector onone end

Strona 45

1INTRODUCTIONArgusScan® is an aggressive, omnidirectional laser barcode scanner ideal forretail, convenience, liquor, and specialty store applications

Strona 46 - Scanner Pinout Connections

46LIMITED WARRANTYThe MS7220 scanners are manufactured by Metrologic at its Blackwood, New Jersey,U.S.A. facility. The MS7220 scanners have a two (2)

Strona 47

47LASER AND PRODUCT SAFETYNoticeThis device complies with Part 15 of the FCC Rules. Operation is subject to thefollowing two conditions: (1) This dev

Strona 48

48LASER AND PRODUCT SAFETYCautionUse of controls or adjustments or performance of procedures other than thosespecified herein may result in hazardous

Strona 49 - Cable Connector Configuration

49PATENTS“Patent InformationThis METROLOGIC product may be covered by one or more of the followingU.S. Patents:U.S. Patent No.;4,960,985; 5,081,342;

Strona 50 - IMITED WARRANTY

50INDEX AAccessories...2Adapter...2, 45Audible ...

Strona 52

July 2003Printed in USA 00-02554B

Strona 53

2SCANNER and AccessoriesBASIC KITPart # DescriptionMS7220 ArgusScan Presentation Scanner00-02407 MetroSelect® Programming Guide**00-02554 MS7220 User’

Strona 54 - INDEX

3GETTING STARTEDTools needed:• Phillips head screwdriver • ¼”-20 wrench• Drill with a #39 drill bit (drill for hard-mount installation only)Slide

Strona 55

4GETTING STARTEDSee the “MS7220 Stands” section of this guide for additional information on the vertical[ MLPN 46-46405 ] and flexible [ MLPN 46-46406

Strona 56 - 00-02554B

5INSTALLATION FOR OCIA INTERFACE1. Follow the “Getting Started” steps onpage 3.2. Turn off the host system.3. Connect the MVC cable to the 10-pinOC

Komentarze do niniejszej Instrukcji

Brak uwag