METROLOGIC INSTRUMENTS, INC. MS7180 OrbitCG™ Presentation Laser Scanner Installation and User’s Guide
6 Figure 5.Figure 7.Figure 6. Figure 8.INTRODUCTION Mounting Specifications Optional Wall/Counter Mount Item Description Qty.a. Locking Plate,
7INSTALLATION RS232, Light Pen Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pi
8 INSTALLATION IBM 46xx 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS7180.
9INSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on th
10 INSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin sock
11INSTALLATION Full Speed or Low Speed USB 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socke
12 INSTALLATION EAS Deactivation SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. The following is
13SCANNER OPERATION POWER SAVE MODES The OrbitCG has five configurable power save modes. Refer to the MetroSelect Configuration Guide (MLPN 00
14 SCANNER OPERATION Primary and Secondary Scan Pattern Modes There are two scan pattern modes available with the MS7180. • The primary scan pa
15SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED 1. The primary (omni) scan pa
Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, tran
16 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED 1. The primary (omni) scan p
17SCANNER OPERATION Audible Indicators When the MS7180 is in operation, it provides audible feedback to indicate the status of the scanner. Eig
18 SCANNER OPERATION Visual Indicators The MS7180 is equipped with a blue and a white LED that indicates the scanner’s state and the status of th
19SCANNER OPERATION Failure Mode Indicators Flashing Blue with One Razzberry Tone This indicates that the scanner has experienced a laser subs
20 SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 17. MS71
21SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F G H J K mm .13
22 SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F G H J K mm - .
23TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3
24 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The unit is trying to scan a particular symbology that is not enabled
25TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The print quality of the bar code is suspect. The aspect ratio of the
iiTABLE OF CONTENTS Introduction Product Overview ... 1 Sc
26 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution RS232 Only The host is receiving data but the data does not look correct. The scanne
27DESIGN SPECIFICATIONS MS7180 Operational Light Source: Visible Laser Diode (VLD) @ 650 nm Laser Power: Less than 1 mW average Normal Depth
28 DESIGN SPECIFICATIONS MS7180 Electrical Voltage Supply: 5VDC ± 0.25V Operating Power: 0.9 W Standby Power: 0.85 W Blink Power Save Mode
29APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER V
30 DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The sca
31DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 LIGHT PEN IBM 46XX KBW USB Expanded ID “]e0” * RSS Limited E
32 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 LIGHT PEN IBM 46XX KBW USB Transmit UPC-A Check Digit * Tr
33DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 LIGHT PEN IBM 46XX KBW USB Nixdorf ID LRC Enabled UPC
34 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 LIGHT PEN IBM 46XX KBW USB Supplements are not Required * T
35UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic’s new line of Flash-based scanners. This program
iiiTABLE OF CONTENTS Troubleshooting Guide ... 23 Design Specifi
36 SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS7180 scanner interfaces terminate to a 10-pin modular socket. The serial # lab
37SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable MLPN 54-54000x -3 straight Pin Function 1
38 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 54-54002x -3 Pin Function 1 Keyboard C
39REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Cau
40 REGULATORY COMPLIANCE EMC Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity: CISPR 24, EN 55024 Class A Devices Unintentional
41REGULATORY COMPLIANCE EMC Class B Devices Unintentional Radiators The following is applicable when the scanner cable is less than 3 meters
42 LIMITED WARRANTY The MS7180 OrbitCG™ scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS7180 OrbitCG
43PATENTS Patent Information This METROLOGIC product may be covered by, but not limited to, one or more of the following U.S. Patents: U.S. Pate
44 INDEX A AC ... see power accessories ...2, 3 adapter ...
45INDEX O operation ...41 P patents...43 PC ...
1INTRODUCTION OrbitCG™ is an aggressive, omnidirectional laser bar code scanner ideal for use in retail, convenience, liquor and specialty stores
October 2006 Printed in the USA 00-02284A
2 INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No. Description MS7180 OrbitCG Presentation Laser Bar Code Scanner 00-02284x MS
3INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No. Description 54-54002x-3 Keyboard Wedge PowerLink Cable 2.1 m (7 ft.) straigh
4 Figure 2. Cable ReleaseINTRODUCTION Scanner Components ITEM NO DESCRIPTION 1 Mode Select Button/CodeGate Button (see page 14) 2 White LED (se
5INTRODUCTION Caution and Serial Number Labels Figure 3. Label Location on the Bottom of the Scanner with Example Caution To maintain com
Komentarze do niniejszej Instrukcji