Metrologic Instruments OrbitCG MS7180 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czytniki kodów kreskowych Metrologic Instruments OrbitCG MS7180. Metrologic Instruments OrbitCG MS7180 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Presentation Laser Scanner

METROLOGIC INSTRUMENTS, INC. MS7180 OrbitCG™ Presentation Laser Scanner Installation and User’s Guide

Strona 2

6 Figure 5.Figure 7.Figure 6. Figure 8.INTRODUCTION Mounting Specifications Optional Wall/Counter Mount Item Description Qty.a. Locking Plate,

Strona 3 - ABLE OF CONTENTS

7INSTALLATION RS232, Light Pen Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pi

Strona 4

8 INSTALLATION IBM 46xx 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS7180.

Strona 5

9INSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on th

Strona 6

10 INSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin sock

Strona 7

11INSTALLATION Full Speed or Low Speed USB 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socke

Strona 8

12 INSTALLATION EAS Deactivation SW1 and SW2 are the switch banks inside the Checkpoint Device that set the deactivation range. The following is

Strona 9

13SCANNER OPERATION POWER SAVE MODES The OrbitCG has five configurable power save modes. Refer to the MetroSelect Configuration Guide (MLPN 00

Strona 10 - INTRODUCTION

14 SCANNER OPERATION Primary and Secondary Scan Pattern Modes There are two scan pattern modes available with the MS7180. • The primary scan pa

Strona 11 - INSTALLATION

15SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED 1. The primary (omni) scan pa

Strona 12

Copyright © 2006 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, tran

Strona 13

16 SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED 1. The primary (omni) scan p

Strona 14

17SCANNER OPERATION Audible Indicators When the MS7180 is in operation, it provides audible feedback to indicate the status of the scanner. Eig

Strona 15

18 SCANNER OPERATION Visual Indicators The MS7180 is equipped with a blue and a white LED that indicates the scanner’s state and the status of th

Strona 16

19SCANNER OPERATION Failure Mode Indicators Flashing Blue with One Razzberry Tone This indicates that the scanner has experienced a laser subs

Strona 17 - SCANNER OPERATION

20 SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 17. MS71

Strona 18

21SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F G H J K mm .13

Strona 19

22 SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F G H J K mm - .

Strona 20

23TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3

Strona 21

24 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The unit is trying to scan a particular symbology that is not enabled

Strona 22

25TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The print quality of the bar code is suspect. The aspect ratio of the

Strona 23

iiTABLE OF CONTENTS Introduction Product Overview ... 1 Sc

Strona 24

26 TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution RS232 Only The host is receiving data but the data does not look correct. The scanne

Strona 25

27DESIGN SPECIFICATIONS MS7180 Operational Light Source: Visible Laser Diode (VLD) @ 650 nm Laser Power: Less than 1 mW average Normal Depth

Strona 26

28 DESIGN SPECIFICATIONS MS7180 Electrical Voltage Supply: 5VDC ± 0.25V Operating Power: 0.9 W Standby Power: 0.85 W Blink Power Save Mode

Strona 27 - TROUBLESHOOTING GUIDE

29APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER V

Strona 28

30 DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The sca

Strona 29

31DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 LIGHT PEN IBM 46XX KBW USB Expanded ID “]e0” *      RSS Limited E

Strona 30

32 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 LIGHT PEN IBM 46XX KBW USB Transmit UPC-A Check Digit *      Tr

Strona 31 - DESIGN SPECIFICATIONS

33DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 LIGHT PEN IBM 46XX KBW USB Nixdorf ID    LRC Enabled    UPC

Strona 32

34 DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT RS232 LIGHT PEN IBM 46XX KBW USB Supplements are not Required *      T

Strona 33 - APPLICATIONS AND PROTOCOLS

35UPGRADING THE FLASH ROM FIRMWARE The MetroSet2 program is a functional component of Metrologic’s new line of Flash-based scanners. This program

Strona 34

iiiTABLE OF CONTENTS Troubleshooting Guide ... 23 Design Specifi

Strona 35

36 SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The MS7180 scanner interfaces terminate to a 10-pin modular socket. The serial # lab

Strona 36

37SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable MLPN 54-54000x -3 straight Pin Function 1

Strona 37

38 SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 54-54002x -3 Pin Function 1 Keyboard C

Strona 38 - Mode Only

39REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Cau

Strona 39 - MLPN 54-54000x-3)

40 REGULATORY COMPLIANCE EMC Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity: CISPR 24, EN 55024 Class A Devices Unintentional

Strona 40 - Scanner Pinout Connections

41REGULATORY COMPLIANCE EMC Class B Devices Unintentional Radiators The following is applicable when the scanner cable is less than 3 meters

Strona 41 - MLPN 54-54214

42 LIMITED WARRANTY The MS7180 OrbitCG™ scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS7180 OrbitCG

Strona 42

43PATENTS Patent Information This METROLOGIC product may be covered by, but not limited to, one or more of the following U.S. Patents: U.S. Pate

Strona 43 - REGULATORY COMPLIANCE

44 INDEX A AC ... see power accessories ...2, 3 adapter ...

Strona 44

45INDEX O operation ...41 P patents...43 PC ...

Strona 45

1INTRODUCTION OrbitCG™ is an aggressive, omnidirectional laser bar code scanner ideal for use in retail, convenience, liquor and specialty stores

Strona 48

October 2006 Printed in the USA 00-02284A

Strona 49

2 INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No. Description MS7180 OrbitCG Presentation Laser Bar Code Scanner 00-02284x MS

Strona 50

3INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No. Description 54-54002x-3 Keyboard Wedge PowerLink Cable 2.1 m (7 ft.) straigh

Strona 51

4 Figure 2. Cable ReleaseINTRODUCTION Scanner Components ITEM NO DESCRIPTION 1 Mode Select Button/CodeGate Button (see page 14) 2 White LED (se

Strona 52 - Printed in the USA

5INTRODUCTION Caution and Serial Number Labels Figure 3. Label Location on the Bottom of the Scanner with Example Caution To maintain com

Komentarze do niniejszej Instrukcji

Brak uwag