Metrologic Instruments TECH 7 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czytniki kodów kreskowych Metrologic Instruments TECH 7. Metrologic Instruments TECH 7 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Installation and User’s Guide

METROLOGIC®INSTRUMENTS, INC.TECH 7®Laser Bar CodeProjection ScannerInstallation and User’s Guide

Strona 2 - Copyright

Parts of Scanner1 Green and Red LEDsWhen the green LED is on, this indicates that the unit is receiving power and the laser is on. When the red LED f

Strona 3 - Table of Contents

7Visual IndicatorsThere is a red and green LED at the top of the scanner. When thescanner is on, the flashing or stationary activity of the LEDs indic

Strona 4

Signaux OptiquesSur la partie supérieure du scanner se trouvent une diode LED rougeet une diode LED verte. Quand le scanner est sous tension, lesdiod

Strona 5 - Unpacking List

Optische AnzeigenAuf dem Scanner befinden sich eine rote und eine grüne Leuchtdiode. Beieingeschaltetem Scanner geben Ihnen die blinkenden bzw. festst

Strona 6 - Scanner Installation

Segnali OtticiSullo scanner si trovano due diodi luminosi: uno rosso e uno verde.Quando lo scanner è inserito, i diodi luminosi, che possono o esserea

Strona 7

11LabelsThere is one label located inside the window of the scanner notingthat this device is a CDRH Class IIa laser product and IEC 825LASERKLASSE 1.

Strona 8 - Stand Installation

Depth of Scan Field for the MS770 ScannerThe depth of field for the scanner is 76mm to 254mm (3.00” - 10.00”)from the laser output window. Pass the s

Strona 9 - Back Plate Installation

Depth of Scan Field for the MS775 ScannerThe depth of field for the scanner is 76mm to 254mm (3.00” - 10.00”)from the laser output window. Pass the s

Strona 10 - Parts of Scanner

MaintenanceSmudges and dirt can interfere with the proper scanning of a barcode. Therefore, the output window will need occasional cleaning. 1. Spray

Strona 11 - Visual Indicators

Appendix ASpecificationsApplication: Industrial Projection ScannerLight Source: Visible Laser Diode 650 ± 5 nm or 670 ± 5 nmCDRH: CLASS IIa laser prod

Strona 12 - Signaux Optiques

Copyright© 2006 by Metrologic Instruments, Inc. All rights reserved. No part of thiswork may be reproduced, transmitted, or stored in any form or by

Strona 13 - Optische Anzeigen

Appendix A (Continued)OperationalDepth of Scan Field: 76mm to 254 mm (3 in to 10 in)Scan Speed: Model 770: 2000 scan lines per secondModel 775: 1200

Strona 14 - Segnali Ottici

17Appendix BPin AssignmentsVersion "1" Pin Assignments for RS-232, OCIA, and Bi-direc-tional RS-232Each TECH 7 scanner has a 19-pin male Mi

Strona 15 - Metrologic

Appendix B (Continued)Version "15" Pin Assignments for Light Pen EmulationEach TECH 7 scanner has a 19-pin male Mil spec connector that islo

Strona 16 - 152 mm [6.00 in]

Appendix CWarranty and DisclaimerLimited WarrantyThe Tech 7 scanners are manufactured by Metrologic at its Blackwood, New Jersey,U.S.A. facility. The

Strona 17 - 229 mm [9.00 in]

Appendix DNoticesThis equipment has been tested and found to comply with limits for a Class A digital device, pursuantto Part 15 of the FCC Rules. The

Strona 18 - Applications and Protocols

Appendix D (Continued)European StandardFunkstöreigenschaften nach EN 55022:1998Standard Europeo21WarningThis is a class A product. In a domestic envi

Strona 19 - Specifications

Appendix EPatents“Patent InformationThis METROLOGIC product may be covered by one or more of thefollowing U.S. Patents:U.S. Patent No. 4,360,798; 4,36

Strona 20 - Appendix A (Continued)

AAC 2Applications 1, 14, 15ASIC 1Atrium option 6Autodiscriminate 1, 16BBack Plate 1, 5, 15Bidirectional RS-232 14, 17CCable 2, 6, 17, 18communication

Strona 21 - Appendix B

SScan pattern 1, 16Scan Speed 16ScanSelect 3ScanSet® 3Service Center 7Specifications 15Stand 1, 4, 15VVisual Indicators 7, 8, 9, 16Voltage 15WWarning

Strona 23 - Appendix C

iiTable of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1Unpacking List . . . . . . . .

Strona 26 - Appendix E

March 2006Printed in the USA

Strona 28

1IntroductionMetrologic's TECH 7®laser bar code projection scanner is encased inan NEMA-12 steel case. The case construction enables the scanner

Strona 29

Scanner InstallationTo maintain compliance with applicable standards, all circuits con-nected to the scanner must meet the requirements for SELV (Safe

Strona 30

Configuration to the Host SystemThe scanner is shipped from the factory programmed to a set ofdefault conditions noted in the ScanSelect™ Scanner Prog

Strona 31

Stand InstallationWith the Metrologic stand (Part #45475), the scanner can be posi-tioned in one of two directions. The two orientation choices are ve

Strona 32 - Printed in the USA

Back Plate InstallationWith the Metrologic back plate (Part #45473), position the scannerin one of two directions. The twoorientation choices are ver

Komentarze do niniejszej Instrukcji