Strona 2

6Figure 5.INSTALLING THE SCANNER TO THE HOST SYSTEMKeyboard Wedge MS9524-47 and MS9544-471. Turn off the PC.2. Connect the 10-pin RJ45 maleconnector

Strona 3 - LOCATIONS

7INSTALLING THE SCANNER TO THE HOST SYSTEMStand Alone Keyboard1. Turn off the host system.2. Connect the 10-pin RJ45 maleconnector into the jack on

Strona 4 - TABLE OF CONTENTS

8INSTALLING THE SCANNER TO THE HOST SYSTEMIntegrated Full Speed USB MS9524-40 and MS9544-401. Turn off the host system.2. Connect the 10-pin RJ45 ma

Strona 5 - INTRODUCTION

9DISCONNECTING THE POWERLINK CABLEBefore removing the cable from the scanner, Metrologic recommends that thepower on the host system is off and the po

Strona 6 - SCANNER AND ACCESSORIES

10HOW TO USE CODEGATE – MS9544TWO MODES OF OPERATION• Auto triggeractivates thelaser• Place thelaser line onthe bar code• Press theCodeGatebutton totr

Strona 7

11HOW TO SCAN PDF BAR CODESOperator Note: PDF-CodeGate is disabled (by default) in all MS9544VoyagerPDF units.1. The auto trigger activates thelaser

Strona 8 - OPERATIONAL TEST

12STAND KITSFree Standing Kits #46-46128a. Stand (MLPN 36-00454)...Qty 1b. Apron (MLPN 50-50440)...

Strona 9 - Figure 4

13ASSEMBLING THE STANDSThere are 2 options for assembling the stand. The first option allows the stand tobe self-supporting and moved freely or place

Strona 10 - Figure 5

14ASSEMBLING THE STAND (CONTINUED)Stand Option 2: Hard-mounted to countertop (continued)For use with kits #46-46128, #46-46351 andMS951 Stand Replace

Strona 11 - Stand Alone Keyboard

15ASSEMBLING THE STAND (CONT.)Wall Mount, Option 1:For Kit #46-46433 orKit #46-46508Step 1:Drill two #39 pilot holes 3.00” apart.Step 2:Attach the Wal

Strona 13 - ONNECTING THE POWERLINK CABLE

16SCANNER PARTSDescription1 White LED2 Yellow LED* * This feature is not available on the MS95243 CodeGate Button* * This feature is not available on

Strona 14 - TWO MODES OF OPERATION

17AUDIBLE INDICATORSWhen the VoyagerPDF is in operation, it provides audible feedback. Thesesounds indicate the status of the scanner. Eight setting

Strona 15 - HOW TO SCAN PDF BAR CODES

18VISUAL INDICATORSThe MS9544 has three LED indicators (blue, white and yellow) located on thehead of the scanner. The MS9524 has two LED indicators

Strona 16 - STAND KITS

19VISUAL INDICATORS (CONTINUED)Alternating Flashing of Blue and WhiteThis indicates the scanner is program mode. A razzberrytone indicates that an in

Strona 17 - ASSEMBLING THE STANDS

20FAILURE MODESOne Razzberry Tone – On Power Up or During ScanningThis indicates the scanner has experienced motor or laserfailureThree Beeps – On Pow

Strona 18 - Figure 27

21PROGRAMMING MODESThe MS9524/44 VoyagerPDF Series has 3 modes of programming.¾ Bar CodesVoyagerPDF or VoyagerPDF with CodeGate can be configured by

Strona 19 - ASSEMBLING THE STAND (CONT.)

22PROGRAMMING MODES (CONTINUED)4. During programming, the motor and laser turn off. YOU CANNOT SCAN ABAR CODE WHILE IN SERIAL PROGRAM MODE.5. There

Strona 20 - SCANNER PARTS

23PROGRAMMING MODES (CONTINUED)EXAMPLE #3:The following example shows the events that occur when an invalid bar codeis sent. This sample will load th

Strona 21 - AUDIBLE INDICATORS

24UPGRADING THE FLASH ROM FIRMWAREThe Meteor™ program is a functional component of Metrologic’s new line ofFlash- based scanners. This program allows

Strona 22 - VISUAL INDICATORS

25LABELSEach scanner has a label on the back of the unit. This label has the modelnumber, date of manufacture, serial number, CE and caution informat

Strona 23 - VISUAL INDICATORS (CONTINUED)

iiLOCATIONS CORPORATE HEADQUARTERS North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO90 Coles Road Tel: 856-228-8100Blackwoo

Strona 24 - FAILURE MODES

26DEPTH OF FIELDFigure 33.Minimum Bar Code Element WidthABCDE FGHJKmm.13 .15 - - .19 - .25 .33 .53 -mils5.2 5.7 - - 7.5 - 10 13 21 -Specifications sub

Strona 25 - ¾ Serial Programming

27DEPTH OF FIELDFigure 34.PDF417 Minimum Bar Code Element WidthABmm.25 .38mils10 15Specifications subject to change without notice.

Strona 26 - PROGRAMMING MODES (CONTINUED)

28IR ACTIVATIONFigure 35.Specifications subject to change without notice.

Strona 27

29APPLICATIONS AND PROTOCOLSThe model number on each scanner includes the scanner number and factorydefault communications protocol.ScannerVersionIden

Strona 28 - MLPN 54-54012) are required

30TROUBLESHOOTING GUIDEThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-Metro or 1-800-436-3876 to

Strona 29 - MAINTENANCE

31TROUBLESHOOTING GUIDE (CONTINUED)Symptoms Possible Causes SolutionThe unit powersup, but does notscan and/orbeep.The bar codesymbology trying tobe s

Strona 30 - DEPTH OF FIELD

32TROUBLESHOOTING GUIDE (CONTINUED)Symptoms Possible Causes SolutionThe unit beepsat some barcodes and NOTfor others of thesame bar codesymbology.The

Strona 31

33TROUBLESHOOTING GUIDE (CONTINUED)Symptoms Possible Causes SolutionAlphacharacters showas lower case.The computer is inCaps Lock mode.Enable Caps Loc

Strona 32 - IR ACTIVATION

34RS-232 DEMONSTRATION PROGRAMIf an RS-232 scanner is not communicating with your IBM compatible PC, key inthe following BASIC program to test that th

Strona 33 - APPLICATIONS AND PROTOCOLS

35DESIGN SPECIFICATIONSDESIGN SPECIFICATIONSOPERATIONALLight Source: Visible Laser Diode 650 nm ± 10 nmLaser Power: Less than 1 mW (peak)Depth of Scan

Strona 34 - TROUBLESHOOTING GUIDE

iiiTABLE OF CONTENTSIntroduction... 1Scanner a

Strona 35

36DESIGN SPECIFICATIONSDESIGN SPECIFICATIONSELECTRICALInput Voltage: 5.0VDC ± 0.25VPower:Operating = 900 mW (typical)Standby = 325 mW (typical)Curren

Strona 36

37DEFAULT SETTINGSMany functions of the scanner can be “programmed” – that is, enabled ordisabled. The scanner is shipped from the factory programmed

Strona 37 - MLPN 00-02544

38DEFAULT SETTINGS (CONTINUED)PARAMETER DEFAULT OCIA RS-232LIGHTPENIBM46XXKBW USBLASEREMULATIONPDF CodeGate InactiveOut-of-Stand* 9 9 9 9 9 9 9PDF Cod

Strona 38 - RS-232 DEMONSTRATION PROGRAM

39DEFAULT SETTINGS (CONTINUED)PARAMETER DEFAULT OCIA RS-232LIGHTPENIBM46XXKBW USBLASEREMULATIONSame symbol rescan timeout250 msecs9 9 9 9 9 9 9Same sy

Strona 39 - DESIGN SPECIFICATIONS

40DEFAULT SETTINGS (CONTINUED)PARAMETER DEFAULT OCIA RS-232LIGHTPENIBM46XXKBW USBLASEREMULATIONParity Space 9 9 9Baud Rate 9600 98 Data Bits97 Data Bi

Strona 40

41DEFAULT SETTINGS (CONTINUED)PARAMETER DEFAULT OCIA RS-232LIGHTPENIBM46XXKBW USBLASEREMULATIONBookland 9 9ascode 399 9 9ascode 39977 (2 digit) Supple

Strona 41 - DEFAULT SETTINGS

42110SCANNER AND CABLE TERMINATIONSScanner Pinout ConnectionsMS9524/44-41RS-232C and Light Pen EmulationPin Function1 Ground2 RS-232 Transmit Output3

Strona 42 - DEFAULT SETTINGS (CONTINUED)

43110SCANNER AND CABLE TERMINATIONSMS9524/44-9 OCIAPin Function1 Ground2 RS232 Transmit Output3 RS232 Receive Input4 RDATA5 RDATA Return6 Clock In7 Cl

Strona 43

44SCANNER AND CABLE TERMINATIONS (CONTINUED)Cable Connector Configurations (Host End)“Standard” PowerLink Cable53-53xxx-3 coiled or 54-54xxx-3 straigh

Strona 44

45SCANNER AND CABLE TERMINATIONS (CONTINUED)Cable Connector Configuration (Host End)Keyboard Wedge PowerLink Cable53-53002 or 54-54002Pin Function1 Ke

Strona 45

1INTRODUCTIONThe VoyagerPDF™ series of scanners has taken the already proven and reliableVoyager series to new levels of ability. With its introducti

Strona 46 - Scanner Pinout Connections

46LIMITED WARRANTYThe MS9524/44 series scanners are manufactured by Metrologic at its Blackwood, NewJersey, USA facility. The MS9524/44 series scanner

Strona 47 - CANNER AND CABLE TERMINATIONS

47Notices and CautionsNoticeThis equipment has been tested and found to comply with the limits for a Class B digital device,pursuant to Part 15 of the

Strona 48 - 53-53213 or 53-530214

48PATENTS“Patent InformationThis METROLOGIC product may be covered by one or more of the following USPatents:US Patent No. 4,958,984; 5,081,342; 5,260

Strona 49

49IndexAAC Input/Outlet...5, 6, 7, 8Accessories ...2Adapter...2A

Strona 50 - LIMITED WARRANTY

50IndexPParts...2Patent...48PC ... 5, 8, 24, 29, 32, 33,

Strona 52

April 2003Printed in the USA 00-02989A

Strona 53

2SCANNER AND ACCESSORIESBASIC KITPart # DescriptionMS9524 orMS9544VoyagerPDF Series Scanner00-02544 MetroSelect Single-Line Programming Guide*00-02990

Strona 54

3SCANNER AND ACCESSORIESOPTIONAL ACCESSORIESPart # Description53-53213USB Power/Communication Cable,3 m (10’) coiled cord, long strain relief, gray53-

Strona 55

4Figure 1.Figure 2.Figure 3.OPERATIONAL TEST1. Connect the 10-pin RJ45male connector into thejack on the VoyagerPDF.You will hear a ‘click’ whenthe c

Strona 56 - Printed in the USA

5INSTALLING THE SCANNER TO THE HOST SYSTEMMS9524-00/9/11/14/41 and MS9544-00/9/11/14/411. Turn off the host system.2. Connect the 10-pin RJ45 maleco