METROLOGIC INSTRUMENTS, INC.IS6520/MS6520 Cubit® SeriesOmnidirectional Bar Code ScannerInstallation and User’s Guide
4rqposnINSTALLING THE IS6520-41/MS6520-41 TO THE HOST SYSTEM1. Turn off the host system.2. Connect the 10-pin RJ45 male connector into the jack on t
5rqposnut&INSTALLING THE IS6520-47/MS6520-47 TO THE PC1. Turn off the PC.2. Connect the 10-pin RJ45 male connector into the jack on the Cubit®IS
6DISCONNECTING THE POWERLINK CABLES FROM THE SCANNERBefore removing the cable from the scanner, Metrologic recommends that thepower on the host system
7SCANNER PARTSA. SpeakerServes as an audible indicator.B. Green & Red LEDsDuring normal operation, the greenLED is on. This indicates that thel
8STANDSFixed Vertical Stand (MLPN 46-46145)Optional purchase.a. Fixed Vertical Stand ... Qty. 1b. #7 x 1.00” Wood Screw ... Qty. 3c. M3 x 0.
9AUDIBLE INDICATORSWhen the IS6520/MS6520 scanner is in operation, it provides audible feedback.These sounds indicate the status of the scanner. Eigh
10FAILURE MODESFlashing Green and One Razzberry ToneThis indicates the scanner has experienced a lasersubsystem failure. Return the unit for repair
11VISUAL INDICATORSThere is a red LED and a green LED on IS6520/MS6520. When the scanner ison, the flashing or stationary, activity of the LEDs indic
12PROGRAMMING MODESThe IS6520/MS6520 Cubit® has 3 modes of programming.Bar Codes: Cubit can be configured by scanning the bar codes located in theMet
13PROGRAMMING MODES (CONTINUED)6. To enter serial program mode, send the following command [stx]999999[etx].7. To exit serial program mode, send the
14PROGRAMMING MODES (CONTINUED)EXAMPLE #3: The following example shows the events that occur when aninvalid bar code is sent. This sample will load t
15LABELSEach scanner has a label on the back of the unit. This label has the modelnumber, date of manufacture, serial number, CE and caution informat
16OPTIMAL LOW AND CLOSE DEPTH OF FIELDMinimum Bar Code Element WidthABCDEFGHJ Kmm- .15 - .17 - - .25 .33 .53 -mils- 5.7 - 6.8 - - 10 13 21 -Note: The
17OPTIMAL HIGH AND NORMAL DEPTH OF FIELDMinimum Bar Code Element WidthABCDEFGHJ Kmm- .15 - .17 - - .25 .33 .53 -mils- 5.7 - 6.8 - - 10 13 21 -Note: T
18FAR DEPTH OF FIELDMinimum Bar Code Element WidthABCDEFGHJ Kmm- .15 - .17 - - .25 .33 .53 -mils- 5.7 - 6.8 - - 10 13 21 -0255075100125150175200250225
19TROUBLESHOOTING GUIDEThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-METRO or 1-800-436-3876 to
20TROUBLESHOOTING GUIDE (CONTINUED)All InterfacesIS6520/MS6520 Series Troubleshooting Guide (continued)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe unitpowe
21TROUBLESHOOTING GUIDE (CONTINUED)All InterfacesIS6520/MS6520 Series Troubleshooting Guide (continued)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONScanner beep
22TROUBLESHOOTING GUIDE (CONTINUED)RS-232 onlyIS6520/MS6520 Series Troubleshooting Guide (continued)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONPowers up OKand
23APPENDIX ADesign SpecificationsOperationalLight Source: VLD 650 ± 10 nm, 0.681 milliwatts (PEAK)Depth of Field: 0 mm to 176 mm (0” to 7”) for 0.33 m
iiLOCATIONS Corporate Headquarters North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO90 Coles Road Tel: 856-228-8100Blackwoo
24APPENDIX A (CONTINUED)Design SpecificationsElectricalPower: 1.0 WInput Voltage: 5 VDC ± 0.25 VOperating Current: 200 mA typical @5VDCDC Transformers
25APPENDIX BDefault SettingsMany functions of the scanner can be "programmed" - that is, enabled ordisabled. The scanner is shipped from th
26APPENDIX B (CONTINUED)Parameter Default RS-232*Light PenDTS/NIXDORF*NCR FNCR SPoll Light Pen SourceaBeeper Tone NormalaaBeep/Transmit SequenceBefore
27APPENDIX B (CONTINUED)Parameter Default RS-232*Light PenTransmit UPC-A Manufacturer ID#*aaTransmit UPC-A Item ID#*aaTransmit Codabar Start/StopChara
28APPENDIX B (CONTINUED)Parameter Default RS-232*Light PenMessage RTS/CTSaXON/XOFF HandshakingaACK/NA KaTwo Digit Supplimentsaas code 39Five Digit Sup
29110APPENDIX CScanner Pinout ConnectionsThe IS6520/MS6520 scanner interfaces terminateto a 10-pin modular jack. The serial # labelindicates the inter
30APPENDIX C (CONTINUED)Keyboard Wedge Powerlink and Adapter Cable (MLPN 54-54008)The Keyboard Wedge PowerLink cable is terminated with a 5-pin DIN fe
31APPENDIX DWarranty and DisclaimerLimited WarrantyThe IS6520/MS6520 Cubit® scanners are manufactured by Metrologic at itsBlackwood, New Jersey, U.S.A
32APPENDIX ENoticesNoticeThis equipment has been tested and found to comply with limits for a Class A digital device, pursuant toPart 15 of the FCC Ru
33APPENDIX E (CONTINUED)European StandardWarningThis is a class A product. In a domestic environment this product may causeradio interference in whic
iiiTABLE OF CONTENTSIntroduction ...1Scanner and Accessori
34APPENDIX FPatents“Patent InformationThis METROLOGIC product may be covered by one or more of the following U.S.Patents:U.S. Patent No.;4,960,985; 5
35INDEXAAC input/outlet...2, 3, 4, 5, 29Accessories ...2Approvals ...15, 32, 33Assignme
36INDEXOOperating current ...24Operating temperture ...24Operation...9, 23, 32Operational.
August 2002Printed in the USA 00-02421A
ivTABLE OF CONTENTSAppendix CScanner Pinout Connections ...29Cable Connector Configuration
1INTRODUCTIONMetrologic's Cubit® is a compact, omnidirectional bar code scanner that can beused as a presentation scanner or as the scanning comp
2SCANNER AND ACCESSORIESThe following is a list of the parts included in the IS6520/MS6520 Kit.• Cubit® IS6520/MS6520 - Omnidirectional Scanning Engi
3QUICK START1. Connect the 10-pin RJ45 male connector into the jack on the Cubit®IS6520/MS6520. You will hear a ‘click’ when the connection is made.2